A yacht or workboat in dry dock is not protected the way it is at sea. The engine room suppression system is frequently disarmed or removed so mechanics can work, fire pumps are out of service because the hull is out of the water, and detection circuits are disconnected while panels and wiring are replaced. The vessel’s own defenses are offline at exactly the moment its fire load and ignition sources are highest.
Refit work brings those ignition sources aboard in volume. Welding and grinding on hull plating, torch cutting during repowers, heat guns on shrink wrap, and electrical work on energized circuits all happen inside spaces loaded with fiberglass, resin, solvent-based coatings, foam insulation, and joinery. Many of the most expensive yard fires start in a confined space below deck, out of sight, after the hot work crew has moved on.
NFPA 312 addresses this directly. It calls for a fire protection plan for vessels under construction, repair, or lay-up, covering hot work control, fire watches, firefighter access, temporary water supply, and what happens to the vessel’s fixed systems while they are impaired. OSHA 29 CFR 1915 Subpart P sets parallel obligations for the employer, including a written fire safety plan and trained fire watch personnel.